Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Fluoresc ; 34(1): 149-157, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37178421

RESUMO

In this study, a simple Schiff base sensor 1-(((4-nitrophenyl)imino)methyl)naphthalen-2-ol(NNM) has been used for chemosensing of metal ions. The metal sensing properties of sensor NNM have been investigated using UV-visible and fluorescence spectroscopic approaches. The spectral investigations revealed a red shift in absorption spectra and quenching in the emission band of the ligand molecule in the presence of Cu2+ and Ni2+ ions. The binding stoichiometry of sensor NNM for the analyte (Cu2+ and Ni2+ ions) has been investigated by the Job's plot analysis and found to be 1:1 (NNM:Analyte). The data of the Benesi-Hildebrand plot demonstrated that NNM detected Cu2+ and Ni2+ ions in nanomolar quantity. The binding insights among NNM and analytes (Cu2+ and Ni2+ ions) have been confirmed by shifted IR signals. Moreover, the reusabilty of the sensor has been investigated using an EDTA solution. In addition, the sensor NNM also successfully applied to real water samples for the identification and measurement of Cu2+ and Ni2+ ions. Hence, this system could be highly applicable in environmental and biological applications.

2.
J Fluoresc ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37971608

RESUMO

Here, we developed a novel isoniazid based fluorescent probe (E)-N'-(thiophen-2-ylmethylene)isonicotinohydrazide (TINH) through simple condensation reaction and employed for selective detection of Pd2+ ions with a low detection limit of 4.102 × 10-11 M. Among the many existing cations, TINH bound Pd2+ ions with an association affinity of 9.794 × 105 M-1. Adding Pd2+ ions to ligand solution increased the absorption intensity in UV-Visible and quenched the emission intensity in fluorescence spectroscopic experiments. More importantly, this TINH complexed to Pd2+ ions in 1:1 stoichiometric ratio. To evaluate the stability of complexed system, pH experiments has been performed. The binding insights among the ligand and Pd2+ ions has been confirmed by IR spectroscopic and MASS spectrometric methods. Additionally, TINH also applied to real water samples for the identification and measurement of Pd2+ ions. Hence, this system could be highly applicable for detection of Pd2+ ions in environmental and industrial samples with in low detection range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...